Telespace Networks
Exploded render of a fiber optic connector showing ferrule, body, spring and housing parts
Rugged and Harsh-Environment Connectors

Harting-Compatible LC Industrial Fiber Connector

LC fiber inside a sealed industrial housing for turbines, panels and plant.

A Harting-compatible LC connector places standard LC fiber connectors inside a Han-type rectangular industrial housing, sealing them against dust, moisture and vibration in wind turbines, substations and factory cabinets. Telespace builds and tests these LC assemblies so the fiber joins the same rugged connector system already used for power and signal.

Housing
Han-type rectangular
Fiber connector
LC
Fiber
SM or MM
Locking
Lever or bayonet
Use
Turbines, substations
Tested
IL every channel
Request a quote

Built in Mumbai and shipped to the US by express air freight, door to door, with DAP or DDP terms on request.

What it is

Industrial cabinets, wind turbines and substations already rely on rectangular heavy-duty connectors of the Han type to join power and signal. A Harting-compatible LC connector brings fiber into that same system: standard LC fiber connectors sit inside a fiber insert, which in turn sits inside a sealed rectangular housing with lever or bayonet locking.

The result is a fiber link that a maintenance crew handles the same way as every other connector on the panel. The housing keeps dust, oil and moisture off the LC end-faces and holds the connection firm under continuous vibration, which is what kills bare patch cords in nacelles and machine bays.

How we build it

The cable is cut to length and stripped, and each fiber is terminated in an LC connector: epoxy, cure, polish and end-face inspection under magnification. The LC connectors are loaded into the insert, the insert into the hood or housing, and the cable gland is tightened to seal and grip the jacket. Each channel is tested for insertion loss through a mated pair and recorded against the assembly label. Dust covers go on before packing.

Where it is used

  • Wind turbine links between nacelle, hub and tower base controllers
  • Substation and switchgear control and protection
  • Factory automation cabinets and machine interfaces
  • Rail, transport and marine control panels

For short, noisy links inside drives and converters, PCF HFBR links are often the lower-cost choice.

Configuring your order

Tell us:

  • Housing type and size already used on your panel, or the mating part number
  • Insert: duplex or quad LC, and any electrical contacts alongside
  • Fiber type: single-mode OS2, multimode OM3 or OM4
  • Cable: length, jacket, armor and gland size
  • Far end: matching housing, LC breakout or another connector
  • Quantity and labelling scheme

Specifications

Technical specifications

Connectors
HousingHan-type rectangular industrial housing with LC fiber insert
Fiber interfaceLC to IEC 61754-20 inside the insert
LockingHousing lever or bayonet per housing type
Optical
Fiber typesSingle-mode OS2, multimode OM3 or OM4
Insertion lossTypically <= 0.3 dB per mated LC pair (SM, UPC)
Environmental
SealingSealed housing; IP rating per housing datasheet, typically IP65 to IP68
Mechanical
VibrationHousing locking holds the insert under turbine and machine vibration

Values are typical. Every assembly is built to order, so final figures are confirmed on your quote and test report.

Configure

Build it to your link

  1. 01

    Duplex LC insert

    One transmit and receive pair.

  2. 02

    Quad LC insert

    Two duplex pairs through one insert.

  3. 03

    Panel or cable housing

    Bulkhead housing for cabinets, hood for the cable end.

What you get

  • Standard LC fiber connectors protected inside an industrial housing
  • Fits the same rectangular connector system used for power and signal in many cabinets
  • Sealed against dust and moisture in nacelles and outdoor kiosks
  • Housing locks hold the link under continuous vibration
  • Single-mode or multimode, duplex or quad

Applications

Where it is used

  • Wind turbine nacelle and tower links
  • Substation and switchgear control
  • Factory automation cabinets and machine interfaces
  • Rail and transport equipment
  • Offshore and marine control panels

FAQ

Questions buyers ask

Why put an LC connector inside an industrial housing?

A bare LC is designed for clean racks. Inside a sealed industrial housing it is protected from dust, oil, moisture and vibration, and it connects with the same robust locking as the power and signal connectors around it.

Can the housing also carry power or signal contacts?

Modular industrial housings can combine fiber and electrical inserts. Tell us the mix you need and we will confirm what fits the housing size.

Do you supply complete assemblies?

Yes. We supply the housing terminated onto cable of the required length, with the LC fibers polished, inspected and tested for insertion loss.

Request a quote

Quote for Harting-Compatible LC Industrial Fiber Connector

Send the length, connectors each end and quantity, or attach a drawing. An engineer replies within one business day with options and a price.

Built in Mumbai and shipped to the US by express air freight, door to door, with DAP or DDP terms on request.

Request a quote