Telespace Networks
Grey fiber optic light-guide cable with metal connector ends for medical illumination
Laser, Sensing and Medical

Fiber Optic Assemblies for Medical Devices

Custom light-guide and fiber assemblies for device manufacturers.

Medical fiber optic assemblies are custom light-guide and fiber cables with connectors matched to a device's light source and instrument, used for illumination, endoscopy and optical sensing. Telespace builds them to the device manufacturer's drawing, with the connector, length and jacket specified by the OEM.

Type
Light guide or fiber cable
Ends
Matched to source and instrument
Build
To OEM drawing
Jacket
Flexible, wipe-clean
Length
Cut to order
Inspected
Every end-face
Request a quote

Built in Mumbai and shipped to the US by express air freight, door to door, with DAP or DDP terms on request.

What it is

Medical fiber optic assemblies carry light into and out of medical devices. The most familiar example is the light-guide cable that runs from an illumination source to an endoscope or examination instrument, but the same techniques serve diagnostic instruments and optical sensors inside monitoring equipment.

Each assembly is specific to a device: the connector at one end must fit the light source, the connector at the other must fit the instrument, and the jacket must survive the cleaning regime the device goes through. We build these assemblies for device manufacturers, to the manufacturer’s drawing.

How we build it

The fiber or fiber bundle is cut to length and bonded into ferrules matched to the device interface. End-faces are polished and inspected under magnification, because alignment and surface quality decide how much light reaches the instrument. The jacket and strain relief are fitted, the ends are capped, and every assembly is labelled for traceability against the order.

We select materials to suit the cleaning or sterilisation method the device manufacturer specifies. Validation of the finished device, including reprocessing and biocompatibility, stays with the manufacturer.

Where it is used

  • Illumination for endoscopy and examination devices
  • Light delivery in diagnostic and laboratory instruments
  • Optical sensing in patient monitoring equipment
  • Dental and surgical lighting

Configuring your order

Please send:

  • Drawing or sample of the assembly, or photos of both connector ends
  • Light source and instrument models the cable connects
  • Length and any bend or flexibility requirement
  • Cleaning or sterilisation method and expected number of cycles
  • Quantity for prototypes and for production

We usually start with prototype assemblies for your evaluation before a production order. Once the design is frozen, production assemblies are built to the same specification and labelled so each one can be traced to its order.

Specifications

Technical specifications

Optical
ConstructionGlass fiber bundle light guide, or single-fiber assembly, per device
TransmissionSpecified against the device light source; confirm per build
Connectors
EndsMatched to the light source and instrument interface, including SMA 905 and custom ferrules
Construction
JacketFlexible jacket chosen for the cleaning and handling regime the OEM specifies
LengthBuilt to the device drawing
Reprocessing
Cleaning and sterilisationMaterials selected to the OEM's stated reprocessing method; validation remains with the device manufacturer

Values are typical. Every assembly is built to order, so final figures are confirmed on your quote and test report.

Configure

Build it to your link

  1. 01

    Illumination light guides

    Fiber bundle cables carrying light from a source to an instrument.

  2. 02

    Sensing assemblies

    Single-fiber or small-bundle cables for optical measurement in devices.

  3. 03

    Custom connector ends

    Ferrules and housings machined or sourced to match the device interface.

What you get

  • Built to the device manufacturer's drawing and connector interface
  • Precise fiber alignment in the ferrule for efficient light transfer
  • Compact, robust connector ends
  • Jacket materials chosen for the specified cleaning regime
  • Every end-face polished and inspected before dispatch

Applications

Where it is used

  • Illumination for endoscopy and examination devices
  • Light delivery in diagnostic instruments
  • Optical sensing in monitoring equipment
  • Dental and surgical lighting

Industries served

FAQ

Questions buyers ask

Do you work with medical device manufacturers?

Yes. We build fiber assemblies to an OEM's drawing and specification. The device manufacturer remains responsible for device-level validation and regulatory approval.

Can these assemblies be sterilised?

We select materials to suit the cleaning or sterilisation method you specify, such as wipe-down, autoclave or low-temperature processes. Tell us the method and cycle count at enquiry so we can confirm suitable materials.

Can you match an existing light-guide cable?

Usually, yes. Send the cable or clear photos of both ends with any markings, plus the light source and instrument models, and we will assess it.

Do you supply custom lengths and connector ends?

Yes. Length, connector interface at each end and jacket are all built to your specification.

Request a quote

Quote for Fiber Optic Assemblies for Medical Devices

Send the length, connectors each end and quantity, or attach a drawing. An engineer replies within one business day with options and a price.

Built in Mumbai and shipped to the US by express air freight, door to door, with DAP or DDP terms on request.

Request a quote